臭氧O3氣體檢知管182SB OZONE 2.5-100ppm Tube 82SB
1. PERFORMANCE 1) Measuring range :10-100 ppm 5-50 ppm 2.5-25 ppm Number of pump strokes 1/2(50ml) 1(100ml) 2(200ml) 2) Sampling time :1.5 minutes/1 pump stroke 3) Detectable limit :1 ppm(100ml) 4) Shelf life :2 years 5) Operating temperature :0~40℃ 6) Reading :Direct reading from the scale calibrated by 1 pump stroke 7) Colour change :Blue→Pale yellow 2. RELATIVE STANDARD DEVIATION RSD-low:10% RSD-mid.:5% RSD-high:5% 3. CHEMICAL REACTION Indigo is oxidized and Isatin is produced. 4. CALIBRATION OF THE TUBE COLOURIMETRY METHOD 5. INTERFERENCE AND CROSS SENSITIVITY 5 10 20 30 40 50 ppm GAS To pump 182SB OZONE Substance ppm Interference Coexistence Nitrogen dioxide 10 Similar stain is produced. The top of discoloured layer becomes unclear and higher readings are given. (NOTE) 1)In case of 1 / 2 pump strokes, following formula is available for actual concentration. Actual concentration=2 ×Reading value 2)In case of 2 pump strokes, following formula is available for actual concentration. Actual concentration=1/2×Reading value C NH HN C O =? O C =? =C C NH C O =? +2O3 ? 2 =O+2O2 |